Quality & Compliance
Starting from contract manufacturing of medical device components, and progressively expanding to FDA registration and finished device manufacturing license.
The quality system is designed to be compliant with, and compatible across, the requirements of ISO 13485, FDA QMSR, and China GMP.
Compliance
Commitment & Milestones
Full Lifecycle Quality
Management

Design Transfer
Raw Material Control
In-process Control
Facility Monitoring
Finished Products Control
Customer Service
NPI
Quality First Service Best
A Robust Quality Culture Is One Where Quality Is Everyone's Responsibility, Embedded In Daily operations, And Driven By Continuous Improvement And A Zero-Defect Mindset.

-
Management Responsibility
Quality Policy
Quality Objectives
Quality Statement
-
Resource Management
Personnel Qualification & Competence
Quality Awareness
Facility & Equipment Management: Standardization & Lean
-
Measurement, Analysis & Improvement
Customer Satisfaction
Quality Improvement & Optimization
Internal Audit & Process Walk
Supply Chain Management
-
Product Realization
NPI Management Potential Risk Identification Control Method Design
Process Control Real-Time SPC System Error-Proofing
Traceability Management
Process Validation & Design Transfer
Comprehensive Design Transfer Enables Seamless Transition From Development To Production, Ensuring Consistent And Compliant Output.
MP
Testing
Dimensional & Geometric Measurement
Material & Chemical
Microbiological & Environmental
Physical & Mechanical
Measurement Laboratory
Precision Dimensional Measurement Using Advanced Systems From Zeiss, Hexagon, Keyence, And Marsurf-With Methods And Standards Aligned To Customer Requirements For Consistent, Reliable Quality Data.
Chemical Laboratory
Chemical testing includes composition analysis, RoHS/halogen screening, EO residual testing, plus purified water monitoring and passivation solution control (concen & pH) to safeguard product quality and process stability.
Microbiology Laboratory
A dedicated team of engineers with pharmacy or pharmaceutical sciences backgrounds performs bioburden testing, endotoxin testing, and parrticulate testing, along with routine monitoring of the Class 8 cleanroom, ensuring full compliance with ChP & USP standards.
Physical Laboratory
Kersen offers complete mechanical characterization of metallic materials and finished devices -from hardness and strength (tensile, flexural, compressive) to modulus, elongation, and yield behavior -delivering reliable data to support material selection and product performance validation.
Equipment Type
Equipment Photo
Function
CMM (ZEISS)

Contact-based automatic measurement of geometric dimensions and form/position tolerances
CMM (Hexagon)

Contact-based automatic measurement of geometric dimensions and form/position tolerances
Bench-type Profile Measuring Instrument

Profile and surface topography measurement
Cylindricity Measuring Instrument

Roundness, cylindricity and related shape and position detection
OMM (OGP)

Non-contact dimensional measurement and laser-assisted measurement
OMM (LUXURY)

Non-contact two-dimensional/three-dimensional dimension measurement
3D Profile Measuring Instrument

Three-dimensional surface profile and height difference measurement
Equipment Type
Equipment Photo
Function
ICP-OES

RSD ≤ 0.5% Metals and some non-metals tested include: Mo, Pb, Zn, W, Ti, Nb, P, V, Cr, Cu, Mn, Ni, Mg, Si, etc.
RoHS & Halogen Testing

Lead (Pb), Mercury (Hg), Cadmium (Cd), Chromium (Cr), Bromine (Br), Chlorine (Cl) Due to sample variations, the internal detection threshold is set at 70% of the RoHS standard.
Gas Chromatograph

Minimum resolution for temperature setting: 0.1°C Relative standard deviation (RSD) of peak area < 1.0% for 6 consecutive injections EO test range: 0.5 μg/mL to 5.0 μg/mL
Constant-Temperature Water Bath

Accuracy: ±0.5°C; temperature display resolution: 0.1°C; Error: ≤±1.0°C
Microbial Limit Tester

Count the colonies on the petri dishes visually. If the average number of colonies on the two plates from the same dilution level is at least 15, then the difference in the number of colonies between the two plates is less than a factor of 1.
Bacterial Concentrator

Count the colonies on the petri dishes visually. If the average number of colonies on the two plates from the same dilution level is at least 15, then the difference in the number of colonies between the two plates is less than a factor of 1.
Equipment Type
Equipment Photo
Function
Laser Dust Particle Counter

Particle Counter: 0.3 μm–10 μm
Total Organic Carbon Analyzer

Test Range: 1–1,500 μg/L
Digital Display Metal Heating Bath

Visual
Constant-Temperature Water Bath

Accuracy: ±0.5°C; temperature display resolution: 0.1°C; Error: ≤±1.0°C Measuring range: Room temperature to 100°C
Equipment Type
Equipment Photo
Function
Metallography

Objective lens and software accuracy: RSD ≤ 0.8%, 5 μm Micrometer-level relative error ≤ ±1% Test range: 25–500x
MTS Universal Testing Machine

Test Accuracy: ≤±0.5% Test Range: 0–300 kN
Hardness Tester

Vickers hardness tester measurement range: 0.49 N to 298 N Brinell hardness tester measurement range: 95.5 to 653
Torsion Testing Machine

Test Accuracy: ≤±0.5% Test Range: 0 N to 1,000 N
Digital Quality Control
-
Real-Time SPC SystemAutomatic data import for CPK and PPK analysis with live process stability monitoring and instant deviation alerts. -
Online Calibration ManagementEmail notifications for calibration duedates and overdue alerts ensuremeasurement equipment remains in spec. -
QR Code Batch TraceabilityFull traceability from raw materials through semi-finished to finished products via the MES system.
Quality Culture & Continuous Improvement
Kersen organizes various quality activities, such as Quality Month, QCC, and skills competitions, to enhance quality awareness and competencies across all employees.
-
2026Kersen organizes various quality activities, such as Quality Month, QCC, and skills competitions, to enhance quality awareness and competencies across all employees. -
2025Through long-term partnerships with top domestic and international medical device companies, we have achieved continuous improvement and sustained growth, earning customer recognition through excellent quality.

 20280728_00.png)




-旧(1)_00.png)
.png)
.png)
.png)
.png)
.png)
.png)
.png)